Engineering analysis + design software

User Area > Advice

Using Joint Elements with Higher Order Elements

It is possible to use higher order elements (i.e. midside nodes present) in conjunction with joint elements but we normally suggest working with low order elements (only corner nodes present) since higher order elements are susceptible to element mechanisms.

If the structure geometry or the variation of results demands higher order elements then consider invoking fine integration (if available), which will eliminate these mechanisms at the slight expense of a slighter stiffer solution. See the section entitled "Recommendation on Usage" in the Element Reference Manual under the specific element type of interest - there are further comments on the appropriateness of the available element integration schemes.

If low order elements are acceptable, then consider the use of an enhanced strain element. These perform extremely well in comparison with their higher order counterparts.

Search for "Use of Joints With Higher Order Elements" in the online help for more information on this subject.


innovative | flexible | trusted

LUSAS is a trademark and trading name of Finite Element Analysis Ltd. Copyright 1982 - 2022. Last modified: November 29, 2022 . Privacy policy. 
Any modelling, design and analysis capabilities described are dependent upon the LUSAS software product, version and option in use.