Engineering analysis + design software

User Area > Advice

Typical warning message from LUSAS Solver text output file (*.OUT):

***WARNING*** FINE INTEGRATION (OPTION 18) HAS BEEN INVOKED BECAUSE THE MULTI-CRACK/CONCRETE MATERIAL MODEL HAS BEEN ASSIGNED (CHKMAS PROCESSOR)


Most common causes & links to solutions 

This is a warning message to inform the user that the Fine Integration option has been set automatically as it is required for the Multi-Crack Concrete material model. This could be set manually via:

File > Model Properties > Solution tab > Element Options > (check) Fine integration for stiffness and mass


innovative | flexible | trusted

LUSAS is a trademark and trading name of Finite Element Analysis Ltd. Copyright 1982 - 2022. Last modified: November 29, 2022 . Privacy policy. 
Any modelling, design and analysis capabilities described are dependent upon the LUSAS software product, version and option in use.